Ford Fokus>> Cooling system>> The pump of a cooling liquid>> Removal and pump installation on engines Zetec-SE
Pump removal spend in the following sequence:
- Disconnect a wire from the negative plug of the storage battery;
- Merge cooling liquid from cooling system as it is described earlier;
- Remove a pump pulley as it is described earlier;
|
Fig. 175. Removal of the pump of a cooling liquid
|
- Remove the pump of a cooling liquid ( fig. 175);
- Clear привалочную a surface on the engine. Old consolidation cannot be used again.
Pump installation spend to sequences, return to removal. Bolts of fastening of the pump tighten the moment 25 Нм. Check up before the first start-up of the engine of a phase timing.
|