Ford Fokus>> Electric equipment>> The generator>> Generator removal
Starter removal spend in a following order.
Cars with engines of 1,4-1,6 l
Disconnect a wire of "weight" from the negative plug of the storage battery;
- Remove a belt of a drive of auxiliary units as it is described earlier;
- Remove a protective cover from a generator wire;
- Separate a contact socket and remove a wire;
- Turn on from below fastening bolts;
- Turn on from above bolts of fastening and a nut;
- Remove the generator;
- Generator installation spend to sequences, return to removal;
- Bolts and nut wrap the moment 45 Нм;
- Tighten fastening of a wire by the moment 8 Нм.
Cars with engines of 1,8-2,0 l
Disconnect a wire of "weight" from the negative plug of the storage battery;
- Remove a belt of a drive of auxiliary units as it is described earlier;
- Remove a protective cover from a generator wire;
- Separate a contact socket and remove a wire;
- Turn away a bolt of fastening of a broad tank;
- Remove a broad tank from a clamp and take aside but so that the liquid did not follow;
- Remove a tank of the hydraulic booster of a steering and take aside so that the liquid did not follow;
- Disconnect a contact socket from the engine;
- Turn away bolts of fastening of the generator and remove it;
- Generator installation spend to sequences, return to removal;
- Wrap bolts of fastening of the generator the moment 25 Нм;
- Tighten a nut of fastening of a wire the moment 8 Нм.
Cars with diesel engines
Disconnect a wire of "weight" from the negative plug of the storage battery;
- Remove a belt of a drive of auxiliary units as it is described earlier;
- Uncover under the engine;
- Remove a protective cover from a generator wire;
- Turn away a nut of fastening of a wire and remove it.
The car with the conditioner
Remove the compressor of the conditioner and take aside;

Fig. 303. Fastening of an arm of a pulley of the generator



- Turn away bolts of an arm of a pulley of the generator (fig. 303);

Fig. 304. Removal of an adapter of the generator



- Remove a generator adapter, having weakened 3 bolts (fig. 304);

Fig. 305. Generator removal



- Turn away bolts of fastening of the generator and remove it (fig. 305);
- Generator installation spend to sequences, return to removal;
- Wrap bolts of fastening of the generator the moment 25 Нм and an adapter — 12 Нм.